How It Works

No cutting. No sample prep. In real time.

The Si-Through-HR is an infrared microscope built specifically for subsurface inspection of silicon and other semiconductor materials. This page explains how it works, what it can image, and whether it fits your application.

Does any of this sound familiar?

You need to see what's happening inside your device — not just on the surface.

  • Your process involves stacked, bonded, or heterogeneous materials, and critical defects may be buried within the stack.
  • Cutting or polishing the sample destroys the very thing you're trying to inspect.
  • You've looked at existing IR microscopes. They cost $100K+ and may still lack the resolution you need.
  • You're not sure anything on the market works for your specific substrate or geometry.
  • You've considered building your own setup, but the optical expertise isn't in-house.

If you checked one or more of these, you're in the right place!

How Infrared Inspection Works: From Sample to Results

You don't need to trust our specs. You need to see your own samples.

Step 1 — Tell us about your application

Substrate material, layer stack, what you're trying to see. A short email or a 20-minute call is enough for us to tell you if it's feasible.

Step 2 — We image your samples

You ship us your samples. We image them using our infrared imaging system and show you the results live on a 15-minute video call. You see real data from your actual device, before you commit to anything.

Step 3 — You decide

If the imaging works for your application, we discuss configurations and pricing.
No pressure, no lengthy sales cycle.

Compatible Semiconductor Materials: What the Si-Through-HR Can Image

Several semiconductor materials become partially transparent at infrared wavelengths, enabling non-destructive imaging of buried structures.

The table below lists the materials we have tested and validated on the Si-Through-HR, along with typical use cases and known limitations.

MaterialTypical ApplicationsLimitations
Silicon Data center transceivers, On-chip photonic routing, Passive waveguides, MEMSNo limitations *
Silicon Nitride (SiN) Low-loss photonic routing, LiDAR, Biosensing, Frequency combsThin films require suitable substrate and stack design.
Indium Phosphide (InP) Integrated lasers and detectors, Telecom transceivers, Coherent systemsImaging depends on substrate thickness and fabrication.
Germanium (Ge) Infrared Photodetectors, High-speed electronics, Semiconductor substratesPerformance depends on thickness.
Chrome (Thin Films) Photomasks, alignment marks, electrodesImaging is limited by film thickness and coverage.

* Without aberration-correcting optics, image sharpness decreases with imaging depth, as it does with all materials. Performance may also decrease in extremely heavily doped silicon. Good imaging performance has been demonstrated in highly doped silicon with resistivity as low as 10 mΩ·cm.

Not seeing your material?

IR Microscopy Image Quality: Si-Through-HR vs. Existing Systems

Same sample. Same magnification. Different technology.

The images on the left were captured with an existing IR microscope equipped with an InGaAs camera, costing $100,000+. The images on the right were captured with the Si-Through-HR microscope.

Image of an integrated silicon photonic chip sandwiched between two 500 µm thick silicon wafers.

The smallest demonstrated feature successfully resolved by the system is a silicon grating with 400 nm line widths.

Real Results : Non-Destructive IR Inspection for Bonding, Alignment, and Beyond

Every application is different. Here are a few examples of what we have explored.

Working on a similar challenge?

Si-Through-HR System Configurations for Semiconductor Inspection

All Si-Through-HR systems use Jay Photonics’ proprietary infrared imaging technology.

The right configuration depends on your sample size, format, and inspection needs.

Your applicationSample formatImaging approachRecommended system
Inspecting bare dies and small silicon samples Small samples with optical access from both sides and at least one polished surfaceTransmissionCompact Si-Through-HR
Inspecting mounted or packaged dies Transmission through the sample is obstructed by the mounting/substrateReflectionConfigurable Si-Through-HR
Inspecting full wafers Supports 4″–8″ wafers and customizable for 12″ wafersTransmission and/or reflectionConfigurable Si-Through-HR
Applications requiring multiple imaging modes Chips or wafersTransmission and reflectionConfigurable Si-Through-HR

Available Add-ons

OptionWhat it helps withCompact Si-Through-HRConfigurable Si-Through-HR
Polarizers Enable stress imaging through stress-induced birefringence.OptionalOptional
Darkfield Reveals hidden details that can be difficult to see with standard illumination, such as microcracksOptionalOptional
Iris diaphragm Controls the illumination aperture to optimize image contrast and depth of fieldOptionalIncluded
Larger-sensor camera Captures a larger area in a single imageOptional

Pricing & Configurations

Compact Si-Through-HR Configurable Si-Through-HR
Standard Si-Through HR Configurable Si-Through HR
Ready-to-buy system for chip inspection Configured for your sample and inspection requirements
Starting at $4,950 USD Starting at $30,000 USD
View product → Contact us →

Not sure if it works for your samples?

The fastest way to find out is to show us what you're working with.

Tell us your substrate, your layer stack, and what you're trying to see. We'll take it from there.